Hach pHD Process pH Sensors for use with Hach's Digital sc Controllers and Digital Gateway.
The inline process pH sensors feature exceptional performance due to the Differential Electrode Measurement Technique. This field-proven technique uses three electrodes instead of the two electrodes used in conventional pH sensors, resulting in unsurpassed measurement accuracy, greater reliability, and less downtime and maintenance.
Hach pH sensors are available in a wide variety of body materials, mounting styles, pH electrode types, and cable connections. PEEK is suitable for most applications, and Ryton is preferred for use in clean water. Use the blue filter bar below to select the right inline process pH sensor for your application.
The smart choice for accurate and reliable online process pH measurement
General Purpose Online Process pH Sensor - pHD Technology, Glass pH Electrode, PEEK Housing, Convertible Mount, 4.5m Cable.
Exceptional Process pH Sensor Performance with the Differential Electrode pHD Measurement TechniqueThis field-proven technique uses three electrodes instead of the two normally used in conventional pH sensors. Process and reference electrodes measure the pH differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These process pH sensors provide greater reliability, resulting in less downtime and maintenance.
Lower Maintenance Needs with the Double Junction Salt BridgeThe double junction salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.
Extended Working Life with the Replaceable Salt Bridge/ProtectorThe unique, replaceable salt bridge holds an extraordinary volume of buffer to extend the working life of the sensor by protecting the reference electrode from harsh process conditions. The salt bridge simply threads onto the end of the sensor if replacement is needed.
Reliability with Built-in Encapsulated PreampEncapsulated construction protects the sensor’s built-in preamp from moisture and humidity, ensuring reliable sensor operation. The preamp in the pHD analog sensor produces a strong signal, enabling the sensor to be located up to 1000 m (3280 ft.) from the analyzer.
Patented TechnologyThe former GLI, now a Hach Company brand, invented the Differential Electrode Technique for pH measurement in 1970. The pHD™ sensor series (U.S. Patent Number 6395158B1, dated May 28, 2002) takes this field-proven technology to a new level.
Cable Length 2:
4.5 m 5-conductor (plus two isolated shields) cable with XLPE (cross-linked polyethylene) jacket; rated to 302 ºF (150 ºC)
Temperature Compensation:
- Automatic with NTC 300 omega thermistor, or manually fixed at a user-entered temperature, additional selectable temperature correction factors (ammonia, morpholine, or user-defined pH/°C linear slope) available for pure water automatic compensation 0.0 - 50 °C
- Automatic with NTC 300 omega thermistor, or manually fixed at a user-entered temperature, additional selectable temperature correction factors (ammonia, morpholine, or user-defined pH/°C linear slope) available for pure water automatic compensation 0.0 - 50 °C